弱電機房工程UPS電池更換及保養方法

來源(yuan): 發布日期: 2020.11.09

弱電機房工程中的UPS電池是非常重要的組成部分,為了保證弱電工程的安全(quan)運(yun)行,我們需要(yao)定期更換UPS電(dian)池,今天本文就(jiu)為(wei)大家(jia)(jia)介(jie)紹一下弱電(dian)機(ji)房(fang)工程(cheng)UPS電(dian)池更換及保(bao)養方法,希望對大家(jia)(jia)有所幫(bang)助。另外,考(kao)慮到更換UPS后備電(dian)池工作具有嚴格的技術性、安全(quan)性以及相(xiang)關的標準規定,機(ji)房(fang)一定要(yao)做好相(xiang)關的安全(quan)保(bao)護措施。

弱電機房工程UPS電池更換及保養方法 具體的實施(shi)過(guo)程如下(xia):

一、準備工作

接(jie)到可對電(dian)池(chi)進行(xing)更換(huan)(huan)工(gong)作的(de)(de)(de)(de)(de)通知(zhi)后,電(dian)池(chi)更換(huan)(huan)實施(shi)工(gong)程師到現場進行(xing)準(zhun)備工(gong)作:確保UPS主機的(de)(de)(de)(de)(de)輸入供電(dian)、新舊蓄電(dian)池(chi)的(de)(de)(de)(de)(de)登記(ji)檢查、機房內消防系(xi)統煙霧探頭(tou)的(de)(de)(de)(de)(de)密封、準(zhun)備二氧化碳滅火器等相關工(gong)作。更換(huan)(huan)電(dian)池(chi)前對UPS主機、舊電(dian)池(chi)組(zu)、電(dian)池(chi)監(jian)測(ce)儀等設備做好相關的(de)(de)(de)(de)(de)登記(ji)記(ji)錄(lu),特別是每層電(dian)池(chi)的(de)(de)(de)(de)(de)擺放(fang)、電(dian)池(chi)監(jian)測(ce)儀的(de)(de)(de)(de)(de)接(jie)線(xian),要(yao)做好標記(ji),畫好聯接(jie)圖。保證電(dian)池(chi)組(zu)更換(huan)(huan)后的(de)(de)(de)(de)(de)效果(guo)和原有的(de)(de)(de)(de)(de)情況保持一致;

二、進行電池更換處理

一(yi)切準備就緒后,對電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)進(jin)行更換(huan)處(chu)理工作,斷開(kai)(kai)UPS主(zhu)機和(he)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)組(zu)(zu)之間的(de)(de)(de)(de)(de)(de)連(lian)接開(kai)(kai)關(guan),使UPS主(zhu)機和(he)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)組(zu)(zu)斷開(kai)(kai)聯接,確(que)保(bao)更換(huan)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)時工作人(ren)員的(de)(de)(de)(de)(de)(de)安全。對原有電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)組(zu)(zu)的(de)(de)(de)(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)進(jin)行拆卸,電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)更換(huan)實(shi)施工程師負責電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)拆卸工作,相(xiang)關(guan)輔助技術人(ren)員進(jin)行新(xin)舊(jiu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)的(de)(de)(de)(de)(de)(de)搬(ban)運工作。在(zai)拆舊(jiu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)時,將(jiang)拆卸下來的(de)(de)(de)(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)連(lian)接線和(he)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)端子的(de)(de)(de)(de)(de)(de)螺絲用盒子整齊的(de)(de)(de)(de)(de)(de)擺(bai)放(fang)好,保(bao)證(zheng)機房內的(de)(de)(de)(de)(de)(de)整潔和(he)清潔。舊(jiu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)拆完后,將(jiang)舊(jiu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)和(he)舊(jiu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)架整齊的(de)(de)(de)(de)(de)(de)擺(bai)放(fang)在(zai)甲(jia)方(fang)規(gui)定的(de)(de)(de)(de)(de)(de)位置(zhi)。將(jiang)新(xin)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)架組(zu)(zu)裝(zhuang)件安放(fang)在(zai)制(zhi)定位置(zhi),同時開(kai)(kai)始(shi)安裝(zhuang)新(xin)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi),將(jiang)新(xin)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)擺(bai)放(fang)在(zai)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)架上(shang),使新(xin)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)在(zai)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)架上(shang)的(de)(de)(de)(de)(de)(de)擺(bai)放(fang)位置(zhi)、方(fang)向調整的(de)(de)(de)(de)(de)(de)最好。在(zai)連(lian)接好一(yi)組(zu)(zu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)后檢(jian)查電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)端子的(de)(de)(de)(de)(de)(de)連(lian)接線是否(fou)牢(lao)固;檢(jian)查電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)組(zu)(zu)的(de)(de)(de)(de)(de)(de)總電(dian)(dian)(dian)(dian)(dian)壓是否(fou)正常等情(qing)況,電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)的(de)(de)(de)(de)(de)(de)正負極要連(lian)接正確(que);

弱電機房工程UPS電池更換及保養方法——欣榮泰工人施工現場

三、檢查總電壓情況

更換(huan)電(dian)(dian)(dian)池工作完畢后,用(yong)萬(wan)用(yong)表檢(jian)查(cha)電(dian)(dian)(dian)池組(zu)(zu)的(de)(de)總電(dian)(dian)(dian)壓(ya)(ya)情況、電(dian)(dian)(dian)池組(zu)(zu)的(de)(de)正(zheng)(zheng)負(fu)極和(he)中性線的(de)(de)接線情況。確(que)保(bao)電(dian)(dian)(dian)池組(zu)(zu)和(he)UPS主(zhu)機(ji)都正(zheng)(zheng)常(chang)(chang)后,合閉電(dian)(dian)(dian)池組(zu)(zu)的(de)(de)開(kai)關,使UPS不間斷電(dian)(dian)(dian)源系統(tong)恢復(fu)正(zheng)(zheng)常(chang)(chang)工作。然后檢(jian)測(ce)UPS的(de)(de)工作電(dian)(dian)(dian)壓(ya)(ya)、電(dian)(dian)(dian)流、充(chong)電(dian)(dian)(dian)電(dian)(dian)(dian)壓(ya)(ya)、工作狀態等情況并做(zuo)好記錄。由一人觀察主(zhu)機(ji)液晶顯示屏里面的(de)(de)參數(shu)和(he)實際(ji)的(de)(de)是(shi)否一致,電(dian)(dian)(dian)池時間參數(shu)進行(xing)調試(shi)(shi)設(she)(she)置,確(que)保(bao)電(dian)(dian)(dian)池在正(zheng)(zheng)常(chang)(chang)的(de)(de)壽(shou)命期間不會出現錯誤的(de)(de)報警提示。UPS主(zhu)機(ji)調試(shi)(shi)正(zheng)(zheng)常(chang)(chang)后,斷開(kai)UPS主(zhu)機(ji)的(de)(de)輸入電(dian)(dian)(dian)源開(kai)關,模擬市電(dian)(dian)(dian)故障中斷,測(ce)試(shi)(shi)UPS系統(tong)是(shi)否能正(zheng)(zheng)常(chang)(chang)由市電(dian)(dian)(dian)轉為電(dian)(dian)(dian)池組(zu)(zu)后備電(dian)(dian)(dian)源供(gong)電(dian)(dian)(dian),確(que)保(bao)機(ji)房機(ji)柜內(nei)的(de)(de)設(she)(she)備正(zheng)(zheng)常(chang)(chang)運行(xing);

四、清潔UPS機房

在電(dian)(dian)(dian)池(chi)更(geng)換工(gong)作完成之(zhi)后(hou),對(dui)UPS房進行打(da)掃清(qing)潔,清(qing)理(li)雜物,保(bao)證UPS房的良好(hao)環境。恢復電(dian)(dian)(dian)池(chi)更(geng)換之(zhi)前,機房內所做的準(zhun)備工(gong)作。而且(qie)應(ying)使新電(dian)(dian)(dian)池(chi)組充(chong)電(dian)(dian)(dian)至(zhi)24小時左右(you),確保(bao)新電(dian)(dian)(dian)池(chi)充(chong)滿電(dian)(dian)(dian)量。

弱電機房工程UPS電池更換及保養方法——欣榮泰施工現場